CDADAwaa soo saaraha la isku halayn karo iyo alaab-qeybiyaha DC-ga wareegga wareegga. Alaabtayadu waa kuwo tayo sare leh, la isku halayn karo, iyo tignoolajiyad ahaan horumarsan. Waxaan ku takhasusnay horumarinta xalal ku habboon warshadaha sida tamarta cusub, oo ku siinaya adeegyo dhammaystiran, hal-joojin OEM ah.
A Xakamaynta wareegga DC waa qalab ilaalin gaar ah oo loogu talagalay in lagu kala gooyo wareegyada tooska ah ee hadda (DC) ee culeyska xad dhaafka ah, wareegga gaaban, ama xaaladaha cilladda. Si ka duwan jabiyayaasha AC ee ka faa'iidaysanaya isdhaafsiga eber ee hadda jira (100-120 jeer ilbiriqsi kasta oo ah 50/60Hz), jebiyeyaasha DC waa inay xoog ku damiyaanjoogto ah, gees aan jiho lahayn taas oo ka maqan sifooyin is-daminta. Farqiga aasaasiga ah wuxuu u baahan yahay tignoolajiyada casriga ah ee deminta arc, taasoo ka dhigaysa jebinta DC jir ahaan ka weyn, ka adag, oo ka qaalisan dhigooda AC.
Xakamaynta wareegyada DC waxay ku shaqeeyaan inta u dhaxaysa kala duwanaanshaha danabka12V ilaa 1500V DC, oo leh qiimaynta hadda jirta2A ilaa 2500A. Waxay u adeegaan sida qaybaha ilaalinta muhiimka ah ee nidaamyada photovoltaic (PV), nidaamyada kaydinta tamarta batteriga (BESS), gaadhi koronto (EV) ku dallaca kaabayaashacture, xarumaha xogta leh qaybinta korontada DC, warshadaha DC kontaroolada motor, iyo hababka korontada badda.
Caqabadda xudunta u ah joojinta DC waxay ku jirtaafiisigiska dabar goynta arc: DC arcs waxay ilaalinayaan tiirarka balasmaha ee heerkulka ka sarreeya 10,000 ° C, waxay u baahan yihiin dhererka qasabka ah, qaboojinta, iyo deionization iyada oo loo marayo meelaha magnetic, arc chutes, iyo qalabka xiriirka gaarka ah.
|
Kala soocidda |
Nooca |
Xaddiga hadda/Voltage |
Astaamaha Muhiimka ah |
|
By Dhismaha |
2A - 125A, 250V - 1000V DC |
DIN-ku-kordhinta tareenada, goobaha safarka ee go'an, PV-guryaha/ganacsiga |
|
|
10A - 2500A, 500V - 1500V DC |
Qaybaha safarka ee la hagaajin karo, awoodda jabinta sare, warshadaha / tamarta |
||
|
630A - 6300A, 1000V DC |
Naqshad la soo baxay, ilaalinta elektarooniga ah, qaybinta korontada |
||
|
Breaker-State State DC |
100A - 5000A, ilaa 1500V DC |
Semiconductor-ku-saleysan, <1ms hawlgalka, wax-soo-bax la'aan, kharash qaali ah |
|
|
By Qiimaynta Voltage |
Voltage hooseeya |
12V - 250V DC |
Gawaarida, badda, isgaarsiinta |
|
Voltage Dhexdhexaad ah (Heerka PV) |
250V - 1000V DC |
Xadhkaha cadceedda PV, sanduuqyada isku-darka, deegaan/ganacsi |
|
|
Korantada Sare |
1000V - 1500V DC |
Utility-cabbir PV, kaydinta batari, EV degdeg ah u dallacaadda |
|
|
Qaabaynta cirifka |
1-cir |
250V DC |
Xadhig-kaliya PV, korantada hoose ee DC |
|
2-Pole (Taxane) |
500V - 750V DC |
Mid-voltage PV, isku xirka taxanaha laba-tiir |
|
|
3-Cul |
750V DC |
Nidaamyada saddexda weji ee DC, warshadaha gaarka ah |
|
|
4-Tiirarka (Taxane) |
1000V - 1500V DC |
PV-korontada sare, batariyada, kaabayaasha EV |
|
|
By Tignoolajiyada Safarka |
Kuleylka-Magnetic |
2A - 800A |
Bimetallic overload + solenoid-gaaban, dhaqaale |
|
Electronic |
100A - 2500A |
Qalloocyada la hagaajin karo, isgaarsiinta |
|
|
Magnetic Kaliya |
10A - 100A |
Meesha gaaban oo kaliya, ilaalinta matoorka, hawlgal degdeg ah |
Magacaabid Halis ah:Dareenka Polarity Jebinta DC waa in lagu calaamadiyaatogan (+) iyo taban (-) terminal, oo leh tilmaamayaasha jihada hadda. Rakibaadda polarity-ka rogaal celiska ah waxay keeni kartaa fashilaad masiibo ah oo ay ugu wacan tahay hab-dhaqanka arc asymmetrical ah.
Si ka duwan AC arcs ee si dabiici ah u bakhtiiya isgoysyada eber ee hadda jira, qaansooyinka DC waxay soo bandhigaan caqabado gaar ah oo deminta:
|
Halbeegga |
AC Arc |
DC Arc |
|
Qaabka mowjadda hadda jira |
Sinusoidal, eber-gudbida 10 ms kasta (50Hz) |
Joogto ah, baaxadda joogtada ah |
|
danabka Arc |
Isbedbedelka hadda |
Deggan, waxay u baahan tahay dabar-goynta khasabka ah |
|
Dabar goynta Arc |
Dabiici ah oo eber ah |
Kordhinta qasabka ah + qaboojinta ayaa loo baahan yahay |
|
Tamarta Arc |
garaacid, celceliska hoose |
Kulayl joogto ah, oo xoog leh |
|
Xidhiidhka xidhashada |
Dhexdhexaad |
Aad u daran iyada oo aan si habboon loo demin |
|
Farqiga loo baahan yahay |
Ka yar |
2-3× ka weyn danab u dhigma |
|
Farsamada |
Farsamaynta |
Codsiga |
Waxqabadka |
|
Qarxinta Magnetic |
Lorentz Force F = I × L × B wuxuu u wadaa qaansada taarikada kala qaybisa 50-200 m/s |
Universal ee DC MCB/MCCB |
Inta badan, kharash-ku-ool ah, 10-20kA jebinta |
|
Arc Chute oo leh taarikada kala-baxa |
Arc wuxuu u qaybsan yahay qaybo taxane ah, la qaboojiyey, deionized |
Halbeegga dhammaan jabiyayaasha DC |
Qaybta muhiimka ah, hoos u dhaca danab kasta saxan kasta 30-50V |
|
Magnets Joogtada ah |
Magnets NdFeB (0.1-0.3T) oo ku toosan dariiqa arc |
Compact DC MCBs |
Ma jirto awood dibadeed, heerkul-ku-joog ilaa 150°C |
|
Gariiradda qaraxda Electromagnetic |
Gariiradda is-tamarisay waxay abuurtaa dhul u dhigma cilladda hadda jirta |
MCB-yada hadda-sare |
Xooggu wuxuu kordhiyaa ilaalinta hadda, la qabsiga |
|
Faragelinta Vacuum |
Arc wuxuu ku bakhtiy meel faaruq ah (ma jirto dhexdhexaad ah ionizable) |
High-voltage DC, gaar ah |
Aad ugu fiican> 1000V DC, cimri dheer, qaali |
|
Qarax Hawada |
Hawo cadaadisku way qaboojisaa oo fidisaa qaansada |
Warshadaha awoodda sare leh, dhaxalka |
Dayactirka sare, oo dhif ah loo isticmaalo naqshadaha casriga ah |
Isla'egta xoogga Lorentz ayaa maamula wax-ka-beddelka DC:
F = I × L × B
Halkee:
F = Ku xoogag (Newtons)
I = Qulqulka hadda jira (Amperes)
L = Dhererka Arc (mitir)
B = Cufnaanta qulqulka magnetic (Tesla)
Xisaabinta Tusaalaha:
Hadda: 1000A
Dhererka Arkada: 0.02m (2cm)
Dhulka magnetic: 0.2T
Xoog: F = 1000 × 0.02 × 0.2 = 4N
Dardargelinta: a = 4N / (5×10⁻ kg/m × 0.02m) = 400,000 m/s²
Dardargelintan aadka u wayn waxay u kaxaysaa qaansada taarikada kala qaybisa millise seconds gudahood, halkaas oo la kala saaro, la qaboojiyo, oo la damiyo.
|
Qaybta Warshadaha |
Codsiga gaarka ah |
Tilmaamaha Caadiga ah |
Shuruudaha Muhiimka ah |
|
Solar PV (Deegaan) |
Ilaalinta xargaha, sanduuqyada isku-darka |
10A-32A, 250V-500V DC, 2-tiir, qalooca Nooca C |
UV caabbinta, IP65 xero, 20kA Icu |
|
Qorraxda PV (Ganacsiga) |
Sanduuqa isku dhafka ah ee ugu muhiimsan, ilaalinta beddelka |
63A-125A, 500V-1000V DC, 4-tiir, 10-20kA Icu |
Meesha sare (60°C), caabbinta hadda jirta |
|
Solar PV (Utility) |
Inverter Central, ururinta DC |
250A-800A, 1000V-1500V DC, DC MCCB, 50kA Icu |
Iskudubarid doorasho, kormeer fog |
|
Kaydinta Tamarta Bateriga |
Ilaalinta batteriga, baska DC |
125A-630A, 750V-1500V DC, safar elektaroonik ah, 4-tiro ah |
Ilaalinta laba jiho, heer-wareeg gaaban oo sarreeya |
|
Dallacaadda EV |
Difaaca degdega ah ee DC, interface batari |
200A-400A, 500V-1000V DC, dulqaad sare |
Hawlgalka soo noqnoqda, rush sare, badbaadada SIL 2 |
|
Xarumaha Xogta |
380V DC qaybinta, ilaalinta UPS |
63A-250A, 380V DC, jabin sare, tamar yar oo ha la soo maro |
Waqtiga ugu yar ee hoos u dhaca, isuduwidda xulashada |
|
Jiidashada tareenka |
Metro, taraamka, tareenka DC |
1000A-4000A, 750V-1500V DC, DC ACB |
adkaysiga farsamada sare, caabbinta gariir |
|
Badda/Dhul-badeedka |
Qaybinta markabka DC, meelaha xeebaha ka baxsan |
100A-400A, 500V DC, daxalka u adkaysta |
Buufin milix ah, kulaylaha, dhicis badan |
Qalabka Ceyriinka ah ee IQC → Farsamaynta Nidaamka Xiriirka → Golaha Arc Chute → Isku dhafka Nidaamka Magnetka → Golaha Mechanism → Qalabaynta Cutubka Safarka → Golaha Hore → Tijaabada Hadda Sare → Ugu Dambeeya QC → Baakadaha
|
Marxalada |
Faahfaahinta Habraaca |
Qodobbada Xakamaynta Tayada |
|
Xiriirinta Farsamaynta |
Silver-tungsten (AgW 70/30) ama copper-tungsten (CuW 80/20) talooyinka xiriirka, brazing to copper side, tirtiridda joomatari samaynta |
Hardness HV 120-180, caabbinta nabaad-guurka arc, iska caabbinta xiriirka <1mΩ, xoogga naxaas> 80MPa |
|
Dhismaha Arc Chute |
Taarikada kala qaybisa dhoobada (6-15 taarikada iyadoo ku xiran danab), orodyahannada birta ah, isdhexgalka magnetka joogtada ah, joomatari qolka arc la hagaajiyay |
Awoodda Dielectric> 3kV, arc deminta wakhtiga <10ms, cufnaanta qulqulka magnetic 0.15-0.25T |
|
Nidaamka Qarxinta Magnetic |
NdFeB meelaynta magnet joogto ah (darajada N52), farsamaynta gabal tiirarka, hagaajinta wareegga magnetka, magdhowga heerkulka |
Cufnaanta qulqulka ± 10% dulqaadka, isugaynta heerkulka -0.1%/°C, iska caabinta demagnetization |
|
Golaha farsamada |
Isbeddel degdeg ah/nabis degdeg ah, kaydinta tamarta guga, isku xirka safar-la'aanta, ilaha cadaadiska xiriirka |
Xawaaraha furitaanka xidhiidhka>1.2 m/s, adkaysiga farsamada 20,000 wareeg, wakhtiga safarka <20ms |
|
Qalabaynta Cutubka Safarka |
Qiyaasida walxaha kulaylka bimetallic (± 5% saxsanaanta), dejinta farqiga solenoid ee magnetka, xaqiijinta qalooca wakhtiga-hadda |
1.05× Safar-la'aan, 1.25× Safarka <1h, 5× Isla markiiba, xog-qorista |
|
Tijaabada Hadda Sare |
Tijaabada duridda aasaasiga ah ee 10kA-20kA, xaqiijinta dabar goynta, cabbirka heerkulka |
Jebinta caddaynta awoodda, xidhashada xidhidhka <5% ka dib tijaabada, soo kabashada dielectric |
|
Qayb |
Tilmaamaha Qalabka |
Heerarka alaab-qeybiyaha |
Guryaha Furaha |
|
Xiriirada ugu muhiimsan |
Silver-tungsten (AgW 70/30) ama copper-tungsten (CuW 80/20) |
ASTM B702, IEC 60368 |
Iska caabbinta nabaad-guurka sare, alxanka-ka-hortagga, dhaqdhaqaaqa 45-55% IACS |
|
Taarikada Arc Chute |
Alumina ceramik (Al₂O₃ 95%) ama steatite |
IEC 60672 |
Iska caabinta kulaylka> 1200 ° C, xoogga dielectric> 15kV / mm, deminta arc |
|
Magnets Joogtada ah |
NdFeB N52 (Neodymium-Iron-Boron) |
IEC 60404-8-1 |
Joogitaanka 1.48T, qasab>1000kA/m, heerkul xasiloon ilaa 150°C |
|
Qaybaha Cirifka Birlabka |
Bir-kaarboon-hooseeya 1008 ama bir silikoon |
ASTM A1008 |
Dheecaan sare, joogsi hoose, hagida qulqulka magnetic |
|
Kiiska la qaabeeyey |
BMC (DMC-2) heerkulbeeye ama PA66 GF30 |
IEC 60664-1, UL 94 V-0 |
Tilmaanta raadraaca>600V, iska caabin kulaylka 180°C, haynta arc |
|
La xidhiidh Springs |
Naxaasta Beryllium (CuBe2) ama birta 301 |
ASTM B196 |
Nolosha daalka>50,000 wareegyo, cadaadis joogto ah, iska caabin daxalka |
|
Terminalka |
Copper C11000 oo leh daasad ama qalin qalin ah |
ASTM B187 |
Cufnaanta hadda 1.5-2.0 A/mm², iska caabin xiriir hoose, iska caabin oksaydh |
|
Qaybaha bimetallic |
Inconel/isku-darka birta baastay |
ASTM B388 |
Heerka leexashada 0.2mm/°C, xasilloonida ± 3%, saxnaanta cabbirka ± 5% |
|
Qaybaha elegtarooniga ah (cutubyada safarka elegtarooniga ah) |
PCB-yada heerka wershadaha, dareemayaasha Hoolka, soo-saareyaasha ARM |
IEC 60721-3-3 |
-25°C ilaa +70°C hawlgalka, EMC Heerka 3, SIL 2 karti |
|
Heerka |
Baaxadda |
Qiimaynta lagu dabaqi karo |
|
IEC 60947-2 |
Qalabka korantada-hooseeya - Wareeg-jareyaasha (waxaa ku jira DC) |
Halbeegga caalamiga ah ee jabiyeyaasha DC ilaa 1500V DC |
|
IEC 60898-2 |
Wareegyada wareegga ee hawlgalka DC (guriga) |
DC MCBs ilaa 125A, 220V DC (1- tiir), 440V DC (2-cir) |
|
IEC 61643-31 |
SPDs ee codsiyada voltaic |
Iskuduwidda ilaalinta qalliinka DC ee jabiyeyaasha |
|
GB/T 14048.2 |
Heerka qaranka Shiinaha |
Shahaadada CCC ee suuqa Shiinaha |
Shuruudaha Imtixaanka DC ee Muhiimka ah:
Imtixaanka hadda culayska leh ee DC: Xaqiijinta goos-goosyada hadda jira halkaas oo wakhtiga wax-soo-saarka uu aad u kordho
Awoodda jebinta wareegga gaaban: Lagu tijaabiyay ugu badnaan danabka DC oo leh waqti cayiman oo joogto ah (saamiga L/R)
Waxqabadka xad dhaafka ah: Xaqiijinta safarka kulaylka ee 1.45 × In 1 saac
|
Qaybta Imtixaanka |
Imtixaan gaar ah |
Shuruudaha Ogolaanshaha |
|
Heerkulka Sare u kaca |
Joogtada joogtada ah ee lagu qiimeeyay In |
Terminalka ≤80K (lacag), ≤65K ( qaawan), kiis ≤40K |
|
Guryaha Dielectric |
U adkeysiga awoodda-soo noqnoqda (2.5kV-3.5kV/1 daqiiqo), kicin (8kV) |
Burbur la'aan, majiro toosan |
|
Astaamaha Jidka |
Culayska xad dhaafka ah: 1.05× Gudaha (safar la'aan), 1.25×In/1.45×In (safar xadka gudahooda) |
Waqtiyada safarka caadiga ah ee qalooca kasta |
|
|
Wareeg gaaban: 5×In, 10× Safar degdeg ah |
<20ms hawlgalka |
|
Waxqabadka Hawlgelinta |
Farsamada: 20,000 wareeg; Koronto: 10,000 wareeg |
<5% leexleex |
|
Jebinta Wareeg-gaaban |
Icu (ugu dambeeya), Ics (adeeg) oo lagu qiimeeyay danab DC |
Joojin guul leh, alxanka xidhiidhka ma jiro |
|
Culayska DC ee Khatarta ah ee Hadda |
Xaqiijinta xaddidaadaha wakhtiga arcing |
Ma jiro gogol-dhaaf xad-dhaaf ah oo ku dhex jira xadka la qiimeeyay |
|
Xaqiijinta Qarxinta Birlabka |
Waqtiga dabar goynta Arc, daacadnimada qolka arc |
<10ms muddada arc, ma jiro jebin qolka |
|
Deegaanka |
Kulayl qoyan, qabow, kulayl qalalan, gariir |
Waxqabad ka dib qaboojinta |
|
Qalab |
Walxaha Kormeerka |
Qorshaha Muunada |
Qalabka |
|
Talooyinka xiriirka Tungsten |
Cufnaanta, qallafsanaanta, nuxurka qalinka, dulqaadka cabbirka |
Dufcaddiiba |
Spectrometer, tijaabiyaha adkaanta, CMM |
|
magnets NdFeB |
Joogista, qasbida, isku xidhka heerkulka, dhejinta |
Dufcaddiiba |
Hysteresisgraph, gariiradda Helmholtz |
|
Taarikada dhoobada |
Xoogga Dielectric, caabbinta shoogga kulaylka, cabbirrada |
Dufcaddiiba |
Tijaabada dielectric, qolka shoogga kulaylka |
|
Sidayaal naxaas ah |
Hab-dhaqanka, adkaanta, dhumucda dhejinta |
Dufcaddiiba |
Mitirka waxqabadka, mikrometer, XRF |
|
balaastiig kululaynta |
Nuxurka dhalada, viscosity, wakhtiga daawaynta, ololka |
Dufcaddiiba |
DSC, tusaha socodka dhalaalka, UL 94 qalab |
|
Saldhig |
Xakamaynta Xakamaynta |
Soo noqnoqda |
Habka |
|
Xidhiidhka brazing |
Heerkulka 800-850 ° C, jawiga, xoogga wadajirka ah |
100kii cutubba |
Thermocouple, tijaabiyaha xiirid, metallografi |
|
Meelaynta Magnet |
Xaqiijinta polarity, cufnaanta qulqulka, toosinta |
Unug kasta |
Mitirka dareeraha, nidaamka aragga |
|
Arc shute shirka |
Kala dheeraynta saxanka, toosinta magnetka, joomatari orodka |
50kii cutubba |
Tag/ma-tag cabbirrada, khariidaynta cufnaanta qulqulka |
|
Habaynta farsamada |
Xawaaraha furitaanka, cadaadiska xidhiidhka, xoogga safarka |
Unug kasta |
Kamarada xawaaraheeda sare leh, cabirka xoogga, kursi otomaatiga ah |
|
Imtixaanka cutubka safarka |
Qalooca wakhtiga-hadda, safar degdeg ah, magdhawga deegaanka |
Unug kasta |
Tijaabada duritaanka aasaasiga ah (10,000A), xog-qorista |
|
Shayga Tijaabada |
Heerka |
Cabbirka Tusaalaha |
|
Xaqiijinta calaamadaynta polarity |
Sax +/-/ calaamadaynta jihada hadda |
100% |
|
Iska caabin xiriir |
<1mΩ tiirkiiba |
100% |
|
Dielectric adkeysiga danab |
2.5kV AC/1 daq |
100% |
|
Iska caabin dahaarka |
>100MΩ @ 500V DC |
100% |
|
Astaamaha dhicidda |
1.05×In, 1.25×In, 5×In, 10×In xaqiijinta |
100% |
|
Shaqada afuufista magnetic |
Tijaabada dabar goynta Arc ee hadda la qiimeeyay |
100% |
|
Hawlgalka makaanikada |
10 wareeg oo damin ah, hawlgal siman |
100% |
|
Kormeer muuqaal & muuqaal ah |
Nadiifinta, gurguurta, calaamadaynta joogtada ah |
100% |
|
Muunad-hadda sare |
Xaqiijinta awoodda jebinta (10kA) |
AQL 0.65 |
|
daacadnimada baakaynta |
Tijaabada tuurista, gariirka (ISTA 3A) |
Inta badan |
|
Qaybta Qalabka |
Tilmaamaha Mashiinka |
Shaqada |
Awood |
|
Xiriirinta Farsamaynta |
Faakiyum foornada naxaasta ah (10⁻³ mbar, 900°C) |
Tungsten-Silver brazing xiriir |
5,000 xiriir/maalintii |
|
Magnet Assembly |
Meelaynta magnetka tooska ah oo leh ogaanshaha polarity |
NdFeB magnet is dhexgalka, xaqiijinta qulqulka |
3,000 oo kulan/maalintii |
|
Soosaarka Arc Chute |
Cadaadiska saxanka dhoobada, toogashada, biraynta |
Soo saarista saxan kala goynta |
10,000 oo saxan maalintii |
|
Golaha farsamada |
Unugyada golaha shaqada |
Isku-dubarid xawaare sare leh, hagaajin |
2,000 unug/maalintii sadkiiba |
|
Qalabka Tijaabada |
Tijaabada durista aasaasiga ah (awoodda 20,000A DC) |
Xaqiijinta safarka-sare ee hadda |
300 unug/maalintii |
|
Qolka tijaabada dabar goynta Arc (sawir xawaare sare leh) |
Falanqaynta dabeecadda Arc, xaqiijinta afuufka |
50 unug/maalintii |
|
|
Qolka tijaabada deegaanka (heerkulka, qoyaanka, gariirka) |
IEC 60068-2 waafaqsanaanta |
100 unug/maalintii |
|
Qaybta Alaabta |
Awoodda bisha |
Waqtiga Hoggaanka caadiga ah |
Awoodda Dalabka Degdegga ah |
|
DC MCB 1P/2P (10A-63A, 250V-500V) |
200,000 oo unug |
4-5 todobaad |
5 maalmood |
|
DC MCB 4P (63A-125A, 1000V) |
100,000 unug |
4-5 todobaad |
7 maalmood |
|
DC MCCB (125A-400A, 500V-1000V) |
30,000 oo unug |
4-5 todobaad |
10 maalmood |
|
DC MCCB (630A-1600A, 1000V-1500V) |
10,000 oo unug |
4-5 todobaad |
2 todobaad |
|
Korantada sare ee DC (1500V+, khaas ah) |
Saldhigga mashruuca |
8-12 toddobaad |
4 todobaad |
|
Waaxda |
Shaqaale |
Khabiir |
Waajibaadka |
|
Injineerinka R&D |
5 injineerada |
Fiisigiska DC arc, jilitaanka goobta magnetic, qalabka xiriirka, qalabka elektarooniga ah |
Horumarka cusub ee jabiyaha DC, faylalka patent-ka (35+ shatiyada), hal-abuurka HVDC |
|
Farsamada injineernimada |
20 injineer |
Vacuum brazing, shirka magnet, farsamaynta dhoobada, automation |
Hagaajinta wax soo saarka, horumarinta wax-soo-saarka (> 98%), warshadaha 4.0 isdhexgalka |
|
Tijaabinta & Xaqiijinta |
15 injineer |
Tijaabada DC-sare ee hadda, falanqaynta baabi'inta arc, jilitaanka deegaanka, EMC |
Iskuduwidda tijaabada nooca (IEC 60947-2), falanqaynta fashilka, shahaado |
|
Codsiga injineernimada |
12 injineer |
Naqshadeynta PV qoraxda, nidaamyada kaydinta baytariga, dallacaadda EV, microgrids DC |
Taageerada farsamada ee macaamiisha, qaabaynta nidaamka, isuduwidda xulashada |
|
Xaqiijinta Tayada |
30 farsamayaqaan |
ISO 9001, ISO 14001, xakamaynta habka tirakoobka, shaybaarka mitirka |
Hantidhawrka alaab-qeybiyaha, hanti-dhawrka habka, ficilka sixitaanka, maaraynta habaynta |
Xaruntayada wax-soo-saarka ayaa ka dhigan15 sano oo takhasus ah ee ilaalinta wareegga DC, oo keenaysa jebiyayaal ka sarreeya heerarka caalamiga ah iyada oo loo marayo:
Xirfadda fiisigiska ArcNaqshado birlabeed leh oo leh joomatari xoog Lorentz ah oo la hagaajiyay, oo lagu gaarayo <10ms arc extinction at 1500V DC
Is dhexgalka toosan: Guriga dhexdiisa tungsten-silver brazing, NdFeB magnet Assembly, iyo wax soo saarka dhoobada dhoobada ah ee hubinta tayada dhamaystiran
Kaabayaasha tijaabada: $4M+ waxa lagu maalgaliyay shaybaaro DC ah oo hadda jira oo awood u leh 20,000A tijaabinta joojinta, dabar goynta sawirka xawaaraha sare (100,000 fps), iyo jilidda deegaanka
Diiradda tamarta la cusboonaysiin karoNaqshado khaas ah oo loogu talagalay PV cadceedda (1000V-1500V), kaydinta baytariga (ilaalinta laba jiho), iyo ku dallaca EV (iska caabin sare leh)
Hal-abuurnimo-goboleed adag: Horumarinta semiconductor-ku salaysan DC jabiyeyaasha ee <1ms hawlgalka ee codsiyada ilaalinta batteriga ee muhiimka ah
Tilmaamaha farsamada, iskudubarid ilaalinta cadceedda PV, naqshadaynta nidaamka kaydinta batteriga, ama jadwalka xisaabinta warshada, kooxdayada injineernimada waxay bixiyaan la tashi toos ah si loo hubiyo in nidaamyada korantada DC-gaagu ay buuxiyaan shuruudaha badbaadada iyo ujeedooyinka isku halaynta shaqada.