Alaabta
Nooca A Hadhaaga Wareegtada Hadda
  • Nooca A Hadhaaga Wareegtada HaddaNooca A Hadhaaga Wareegtada Hadda
  • Nooca A Hadhaaga Wareegtada HaddaNooca A Hadhaaga Wareegtada Hadda
  • Nooca A Hadhaaga Wareegtada HaddaNooca A Hadhaaga Wareegtada Hadda

Nooca A Hadhaaga Wareegtada Hadda

Ka soo iibso CDADA Nooca A Haraaga Wareegga Hadda Jooga ee Shanghai DADA Electric, waxaanu leenahay waayo-aragnimo ka badan 40 sano, wuxuu noqon karaa alaab-qeybiyahaaga. EN/IEC 61008-1 shahaado, 2P/4P, 16-100A, 30mA/100mA fursadaha. Wuxuu ogaadaa AC + qulqulka qulqulka DC IP20, DIN tareen Buur, adkaysi u leh. Ku habboon guryaha casriga ah & muraayadaha ganacsiga.

Hubi badbaadada shakhsi ahaaneed iyo dabka ee deegaanka hodanka ku ah maanta ee CDADA Nooca A Hadhaaga Wareegga Joogtada ah (RCCB), waxaan ku siin karnaa qiimo toos ah warshadda. Waxay ka gudubtaa ogaanshaha aasaasiga ah ee AC - waxay si kalsooni leh ugu socotaa labadaba sinusoidal AC iyo qulqulka qulqulka haraaga DC ee ay abuuraan aaladaha caadiga ah sida dabaysha taleefanka, darawalada LED-yada, kombuyuutarrada, iyo aaladaha xawaaraha beddelka ah.

Waxaa lagu heli karaa qaabeynta 2P (1+N) iyo 4P (3+N) oo leh qulqulo la qiimeeyay min 16A ilaa 100A iyo dareenka 10mA, 30mA, 100mA, ama 300mA, waxaa loogu talagalay guryo casri ah, xafiis, iyo qalab ganacsi oo fudud.

Iyada oo leh 6kA qiimeynta gaaban ee shuruudaysan, ilaalinta IP20, iyo ikhtiyaarrada laba-geesoodka ah (lug/pin), CDADA Nooca A RCCB wuxuu isku daraa badbaadada, isku halaynta, iyo naqshadaynta rakibaha-dhammaan waxaa taageeray u hoggaansanaanta caalamiga ah.

Type A Residual Current Circuit Breaker

Tilmaamaha Muhiimka ah

Nooca Alaabta: Nooca A RCCB (Hadhaaga Wareegga Wareega ee hadda jira oo aan lahayn ilaalin xad dhaaf ah)
Heerka: EN/IEC 61008-1
Tiirarka: 2P (1+N) ama 4P (3+N)
Hadda lagu qiimeeyay (guda): 16A, 25A, 32A, 40A, 63A, 80A, 100A
Voltage la qiimeeyay: 2P:
230V AC 4P:
230/400V AC Dareenka Hadhaaga ah (I△n):
10mA, 30mA, 100mA, 300mA Hadda Socod La'aan:
0.5 × I△n Waqtiga safarka ee I△n:
≤ 0.1 ilbiriqsi Xaaladda Xaalad-Gaaban ee Hadda (Inc):
6kA Samaynta & Jebinta Awoodda (I₄m):
500A (gudaha ≤ 40A)
630A (gudaha ≥ 63A)
Korontada u adkaysta (Uimp):
6000V Heerkulka shaqada:
-25°C ilaa +40°C Heerka Ilaalinta:
IP20 Koritaanka:
35mm DIN tareenada (EN 60715 waafaqsan) Terminalka:
Nooca lugaha ama nooca pin, wuxuu taageeraa fiilooyinka ilaa 35mm² Tilmaame Muuqaal:
Casaan = ON (xiriiradu way xiran yihiin), Cagaar = OFF (xiriiradu way furan yihiin) Habka Safarka:
Siidaynta elektromagnetic-ka ilaalinta korantada isbedbedelka


Maxaad u dooratay CDADA Nooca A RCCB?

★  Waxay ogaadaa khataraha daadsanaanta adduunka ee-dhabta ah

Si ka duwan Aaladaha Aasaasiga ah ee Nooca AC ah, Nooca CDADA A waxa uu ka jawaabaa labada AC iyo garaaca DC- oo lama huraan u ah badbaadada guryaha iyo xafiisyada ay ka buuxaan sahayda korantada ee nooca beddelka ah, rogayaasha, iyo dabaysha EV.

★ Wax dhib ah ma jiro

Shaandhaynta horumarsan waxay hubisaa difaaca xasarada korantada iyo qulqulka ku meel gaadhka ah ee aan dhibka lahayn, iyadoo wali dammaanad qaadaysa <0.1s wakhtiga safarka ee dareenka la qiimeeyay.

★ Mawqifka Muuqaalka Cad

Tusiyaha booska xidhiidhka cas/cagaarku waxa uu ogolaadaa xaqiijinta degdega ah ee gobolka jabiyay—muhiim ah inta lagu jiro dayactirka ama hubinta degdega ah.

★ Xadhkaha dabacsan & Waafaqid Sare

Waxay taageertaa xargaha lugaha ama biinanka iyo fiilooyinka 35mm², taasoo ka dhigaysa mid la jaan qaadi karta baska iyo kirishbooyada dabacsan ee baalal casri ah.

Type A Residual Current Circuit Breaker

★ Laba rivet oo dheeraad ah

adkaanta daaska ee aagga isku xirka kirishbooyada oo kordhay iyadoo ay ugu wacan tahay laba jeex oo dheeri ah iyo saxanad adag

Type A Residual Current Circuit Breaker

★ DIN xadiidka xadiidka

Rakibaadda degdega ah iyo isku halaynta dheeraadka ah ee ku dhejinta tareenada DIN sababtoo ah daboolka oo leh labanlaab quful

Type A Residual Current Circuit Breaker

★ U Hogaansanaanta Caalamiga ah, Qiimaha Maxaliga ah

shahaado siisay IEC/EN 61008-1, oo ku habboon EU, Bariga Dhexe, Afrika, iyo suuqyada Aasiya - oo leh qiime tartan ah oo ka yimid soo-saare Shiinees ah oo lagu kalsoonaan karo.

Type A Residual Current Circuit Breaker

Codsiyada caadiga ah

Type A Residual Current Circuit BreakerGuryaha Casriga ah: Wareegyada godka leh ee TV-yada, Laptop-yada, qalabka elektarooniga ah ee jikada

Type A Residual Current Circuit BreakerXafiisyada: Qolalka IT-ga, xargaha korontada ee goobta shaqada

Type A Residual Current Circuit BreakerTafaariiqda: Nidaamyada POS, calaamadaha dhijitaalka ah, iftiinka LED

Type A Residual Current Circuit BreakerDhibcaha Dallacaadda EV: Lakabka ilaalinta aasaasiga ah (oo lagu lammaaniyay qalab xad dhaaf ah)

Type A Residual Current Circuit BreakerRakibaadaha la cusboonaysiin karo: rogayaasha cadceedda oo dhalinaya daadinta garaaca wadnaha ee DC

Type A Residual Current Circuit Breaker

FAQ

Q1: Waa maxay faraqa u dhexeeya Nooca A iyo Nooca AC RCDs?

A1: Nooca AC waxa ay ogaataa oo kaliya in ay si siman u dareeraan sinusoidal AC. Nooca A waxa uu ogaadaa AC iyo garaaca DC labadaba (tusaale, saxayaasha ku jira xajiyeyaasha taleefanka, darawalada LED, ama mishiinada dharka). Wareeg kasta oo leh qalabka elektiroonigga ah, Nooca A waxaa looga baahan yahay koodhka koronto ee casriga ah.


Q2: Nooca 30mA ee RCD ma ku filan yahay ilaalinta shakhsi ahaaneed?

J2: Haa. 30mA waa heerka caadiga ah ee ilaalinta naxdinta naf-badbaadinta IEC kasta. Nooca CDADA A wuxuu hubinayaa inuu shaqeeyo xitaa haddii qaladku ay ku jiraan qaybaha DC-ka dhigaya inay ka badbaadsan yihiin Nooca AC xaaladaha dhabta ah ee adduunka.


Q3: Kani RCCB ma bixiyaa culeys xad dhaaf ah ama ilaalin gaaban oo wareeg ah?

J3: Maya. Kani waa RCCB saafi ah (ma jirto ilaalin xad dhaaf ah). Waa in si taxane ah loogu isticmaalo MCB ama fiyuus si looga ilaaliyo culayska xad dhaafka ah iyo wareegyada gaaban.


Q4: Ma u isticmaali karaa habka dhul-beereedka TT?

A4: Haa—Nooca A Haraaga Wareegga Wareegga ah ee hadda jira ayaa caadi ahaan loo adeegsadaa nidaamyada TT, gaar ahaan 100mA ama 300mA ee ilaalinta dabka ee qofka dakhliga soo gala, iyo 30mA wareegyada ugu dambeeya.


Q5: Maxaad CDADA uga doorataa noocyada kale ee Nooca A?

A5: CDADA waxay bixisaa:

● Run IEC 61008-1 waafaqsanaanta warbixinnada imtixaanka

● Ikhtiyaarada labada terminal (lug/pin) ee fiilooyinka dabacsan

● Heerka xiriirka midab-sumadeysan (cas/cagaar)

● Naqshadaynta difaac-difaaca-ma jiro safarro been ah

● OEM-diyaar u ah: qiimaha badan, dukumentiyada Ingiriisiga, muunad degdeg ah

Type A Residual Current Circuit Breaker



Hot Tags: Nooca A Hadhaaga Wareegtada Hadda, Shiinaha, Soo-saare, Soo-saare, Warshad
Soo dir weydiin
Macluumaadka Xiriirka

Ku Fur Xalka Korontada Caadiga ah 24 Saac gudahood!

Waa maxay sababta aad wax uga waydiinayso Soosaaraha Sare ee Shiinaha?

✅ Qiimaha Warshada Tooska ah

Kharashka dhexdhexaadiyaha goo! Warshad ISO 9001-shahaadad ka haysta oo Shiinaha ku taal, waxaanu bixinaa MCCB-yada qaaliga ah, MCB-yada, iyo jabiyayaasha cadceedda DC heerar tartan ah — oo ay taageerayaan shahaadooyin CE, KEMA, iyo ASTA.

40+ sano oo OEM/ODM khibrad u leh

Wax ka beddel khadadka, sumadaha, ama faahfaahinta farsamada si dadaal la'aan ah. Kooxdayada R&D (60+ patents) waxay gacanta ku hayaan:

Korantada gaarka ah/qiimaynta hadda

Baakadaha calaamadeysan

Samaynta degdega ah (tusaale 7 maalmood gudahood)

3 Milyan+ Cutubyo Awood Sannadeedka ah

Ma jiro amar aad u weyn ama degdeg ah! Warshadayada 52,400㎡ waxay dammaanad qaadeysaa:

◆ 15-maalmood wakhtiyada hogaanka ah ee dalabaadka badan

◆ MOQ-yada dabacsan

◆ Imtixaan adag oo ASTM/UL ah

✅ U Hogaansanaanta Caalamiga ah, Dhibka eber

Waxaan xallinaa caqabadaha dhoofinta ee 45+ waddan:

RoHS/REACH dukumeenti

Shahaadooyinka gobolka-gaarka ah

Jebinta cadceedda DC ee mashaariicda cagaaran ee EU

X
Waxaan isticmaalnaa cookies si aan kuu siino khibrad wax barasho oo wanaagsan, u falanqeyso taraafikada goobta iyo shaqsiyeynta macluumaadka. Isticmaalka boggan, waxaad ogolaatay isticmaalkayada cookies-ka.Siyaasadda Qarsoonnimada
DiidAqbal